The Useful Life of Reinforced Concrete Structures with Reinforcement Corrosion Due to Carbonation in Non-Aggressive and Normal Exposures in the Spanish Mediterranean

Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10045/121867
Información del item - Informació de l'item - Item information
Título: The Useful Life of Reinforced Concrete Structures with Reinforcement Corrosion Due to Carbonation in Non-Aggressive and Normal Exposures in the Spanish Mediterranean
Autor/es: Saura Gómez, Pascual | Rizo-Maestre, Carlos | Echarri-Iribarren, Víctor
Grupo/s de investigación o GITE: Materiales y Sistemas Constructivos de la Edificación | Grupo de Investigación en Restauración Arquitectónica de la Universidad de Alicante. GIRAUA-CICOP | Tecnología y Sostenibilidad en Arquitectura
Centro, Departamento o Servicio: Universidad de Alicante. Departamento de Construcciones Arquitectónicas
Palabras clave: Corrosion | Carbonation | Start life | Propagation life | Useful life | Environment
Área/s de conocimiento: Construcciones Arquitectónicas
Fecha de publicación: 19-ene-2022
Editor: MDPI
Cita bibliográfica: Saura-Gómez P, Rizo-Maestre C, Echarri-Iribarren V. The Useful Life of Reinforced Concrete Structures with Reinforcement Corrosion Due to Carbonation in Non-Aggressive and Normal Exposures in the Spanish Mediterranean. Materials. 2022; 15(3):745. https://doi.org/10.3390/ma15030745
Resumen: Some reinforced concrete structures must be repaired at an early stage in their life due to the oxidation processes suffered by their reinforcements; such processes involve serious pathologies that affect the stability and safety of buildings. Spanish legislation distinguishes several classes of environments, with non-aggressive and normal exposure providing a longer useful life of the structure. The present study shows that some structural elements in reinforced concrete, mainly the pillars in the area of contact with the ground, are exposed to significant corrosion by carbonation. This position of the structural elements dramatically and abruptly shortens the useful life of the models provided for the current regulations. A total of 17 pillars in 10 buildings of different ages and locations in the Spanish Mediterranean area, not subject to the presence of chlorides, have been analyzed. These buildings are situated in environments considered by the standard as normal and non-aggressive. The actual carbonation that these elements present have been compared with that which can be derived from the model established by Spanish regulations. Of these pillars, 14 present a carbonation higher than that derived from the model, and the last three pillars largely conform to the figures of the model. This significant deviation shows the need for a revision of the Spanish EHE 08 regulation, which should include aspects such as the action of dampness by capillarity and the differences in electrochemical potential between the different materials.
URI: http://hdl.handle.net/10045/121867
ISSN: 1996-1944
DOI: 10.3390/ma15030745
Idioma: eng
Tipo: info:eu-repo/semantics/article
Derechos: © 2022 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
Revisión científica: si
Versión del editor: https://doi.org/10.3390/ma15030745
Aparece en las colecciones:INV - MSCE - Artículos de Revistas
INV - GIRAUA-CICOP - Artículos de Revistas
INV - TSA - Artículos de Revistas

Archivos en este ítem:
Archivos en este ítem:
Archivo Descripción TamañoFormato 
ThumbnailSaura-Gomez_etal_2022_Materials.pdf3,82 MBAdobe PDFAbrir Vista previa


Este ítem está licenciado bajo Licencia Creative Commons Creative Commons