Influence of the invariant refraction assumption in studies of formulas for monofocal and multifocal intraocular lens power calculation

Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10045/121686
Información del item - Informació de l'item - Item information
Título: Influence of the invariant refraction assumption in studies of formulas for monofocal and multifocal intraocular lens power calculation
Autor/es: Fernández, Joaquín | Rodríguez-Vallejo, Manuel | Martínez, Javier | Burguera, Noemi | Piñero, David P.
Grupo/s de investigación o GITE: Grupo de Óptica y Percepción Visual (GOPV)
Centro, Departamento o Servicio: Universidad de Alicante. Departamento de Óptica, Farmacología y Anatomía
Palabras clave: Prediction error | Formula | Intraocular lens | Monofocal | Multifocal
Área/s de conocimiento: Óptica
Fecha de publicación: 8-feb-2022
Editor: Springer Nature
Cita bibliográfica: International Ophthalmology. 2022, 42: 2417-2424. https://doi.org/10.1007/s10792-022-02241-5
Resumen: Purpose To assess the influence in paired design studies of formulae comparison for intraocular lens (IOL) power calculation of using a single formula for deciding the implanted power with monofocal (mIOL) and multifocal (MIOL) lenses. Design Retrospective observational. Methods Ninety-six right eyes were retrospectively analyzed. Eyes were assigned in two independent groups, SG and HG, depending on the formula used for deciding the implanted power, SRK-T (n = 54) and Haigis (n = 42), respectively. Median absolute prediction error (MedAE) was evaluated between independent samples (SRK-T in SG vs Haigis in HG) and between paired samples (SRK-T vs Haigis in both SG and HG). Percentages of eyes within a specific range of prediction error (PE) were also calculated for both, the standard steps and the clinically relevant steps. Results MedAE difference was lower than 0.09 D between both formulas for the comparison of independent samples in the mIOL (p = 0.62) and MIOL (p = 0.83) groups. However, paired samples resulted in better MedAE for SRK-T in the SG (0.14 D lower, p = 0.003) and for Haigis in the HG (0.07 D lower, p = 0.015), but only in the mIOL group. These small differences were also manifested, but not reaching statistical significance (p > 0.05), in the percentage of eyes achieving a specific range of PE, especially in the mIOL group. Conclusions A small superiority for the formula used for selecting the final implanted IOL power can appear in studies following current standards. These studies should clearly specify which formula was used for selecting the implanted power.
URI: http://hdl.handle.net/10045/121686
ISSN: 1573-2630
DOI: 10.1007/s10792-022-02241-5
Idioma: eng
Tipo: info:eu-repo/semantics/article
Derechos: © The Author(s), under exclusive licence to Springer Nature B.V. 2022
Revisión científica: si
Versión del editor: https://doi.org/10.1007/s10792-022-02241-5
Aparece en las colecciones:INV - GOPV - Artículos de Revistas

Archivos en este ítem:
Archivos en este ítem:
Archivo Descripción TamañoFormato 
ThumbnailFernandez_etal_2022_IntOphthalmol_final.pdfVersión final (acceso restringido)430,99 kBAdobe PDFAbrir    Solicitar una copia


Todos los documentos en RUA están protegidos por derechos de autor. Algunos derechos reservados.