Comparative Analysis of Two Clinical Diagnostic Methods of the Corneoscleral Geometry

Por favor, use este identificador para citar o enlazar este ítem: http://hdl.handle.net/10045/118412
Información del item - Informació de l'item - Item information
Título: Comparative Analysis of Two Clinical Diagnostic Methods of the Corneoscleral Geometry
Autor/es: Bataille, Laurent | Molina-Martín, Ainhoa | Piñero, David P.
Grupo/s de investigación o GITE: Grupo de Óptica y Percepción Visual (GOPV)
Centro, Departamento o Servicio: Universidad de Alicante. Departamento de Óptica, Farmacología y Anatomía
Palabras clave: Corneoscleral topography | Eye surface profiler | Profilometry | Scheimpflug imaging | Ocular sagittal height | Conjunctiva
Área/s de conocimiento: Óptica
Fecha de publicación: oct-2021
Editor: Wolters Kluwer
Cita bibliográfica: Eye & Contact Lens: Science & Clinical Practice: 2021, 47(10): 546-551. https://doi.org/10.1097/ICL.0000000000000785
Resumen: Purpose: To compare the sagittal height (SH) measurements and best fit sphere (BFS) scleral curvature obtained with two different diagnostic technologies. Methods: Prospective, nonrandomized, and comparative study analyzing 23 healthy eyes of 23 patients (age, 14–52 years) was conducted. A complete eye examination was performed including a corneoscleral topographic analysis with the Scheimpflug camera–based system Pentacam (Oculus GmbH, Wetzlar, Germany) and afterward with the Fourier domain profilometer Eye Surface Profiler (ESP) (Eaglet-Eye, Houten, the Netherlands). Differences between devices in temporal SH (TSH), nasal SH (NSH), and mean SH (MSH) measurements at 13- and 15-mm chord length and in scleral BFS were analyzed. Results: Statistically significant differences were found in TSH, NSH, and MSH obtained with Pentacam and ESP (P≤0.017), with a range of agreement from 0.21 to 1.28 mm, and a clear trend of the Pentacam system to provide higher SH measurements. Significant differences were found between Pentacam scleral BFS and ESP outer BFS (P<0.001) (range agreement, 3.57 mm). Significant correlations were found between spherical equivalent and differences between devices in 15-mm TSH (r=0.485; P=0.048), as well as between the difference between devices for some SH measurements and the magnitude of such SH values (r≥0.504; P≤0.014). Conclusion: Sagittal height and scleral BFS measurements obtained with the two devices are not interchangeable, with an increased difference in SH measures between devices in eyes with less myopic refractive error and increased SH values.
Patrocinador/es: This article is funded by the Project UAIND18-06B of the University of Alicante within the program “Ayudas destinadas a la formación predoctoral en colaboración con empresas 2018” supported by the Vicerrectorado de Investigación y Transferencia de Conocimiento. The author D.P. Piñero has been also supported by the Ministry of Economy, Industry and Competitiveness of Spain within the program Ramón y Cajal, RYC-2016-20471.
URI: http://hdl.handle.net/10045/118412
ISSN: 1542-2321 (Print) | 1542-233X (Online)
DOI: 10.1097/ICL.0000000000000785
Idioma: eng
Tipo: info:eu-repo/semantics/article
Derechos: © 2021 Contact Lens Association of Ophthalmologists
Revisión científica: si
Versión del editor: https://doi.org/10.1097/ICL.0000000000000785
Aparece en las colecciones:INV - GOPV - Artículos de Revistas

Archivos en este ítem:
Archivos en este ítem:
Archivo Descripción TamañoFormato 
ThumbnailBataille_etal_2021_Eye&ContactLens_final.pdfVersión final (acceso restringido)300,26 kBAdobe PDFAbrir    Solicitar una copia


Todos los documentos en RUA están protegidos por derechos de autor. Algunos derechos reservados.