Minimal Stabilization Time for Ultra-short Heart Rate Variability Measurements in Professional Soccer
Empreu sempre aquest identificador per citar o enllaçar aquest ítem
http://hdl.handle.net/10045/110909
Títol: | Minimal Stabilization Time for Ultra-short Heart Rate Variability Measurements in Professional Soccer |
---|---|
Autors: | Forner-Llacer, Francisco | Aranda-Malaves, Rodrigo | Aranda, Rafael | Calleja González, Julio | Pérez Turpin, José Antonio | Gonzalez-Rodenas, Joaquin |
Grups d'investigació o GITE: | Grupo de Investigación en Ciencias de la Actividad Física y el Deporte (GICAFD) |
Centre, Departament o Servei: | Universidad de Alicante. Departamento de Didáctica General y Didácticas Específicas |
Paraules clau: | Training status | Fatigue-recovery process | HRV | Professional soccer |
Àrees de coneixement: | Educación Física y Deportiva |
Data de publicació: | 22-de juliol-2020 |
Editor: | Georg Thieme Verlag KG |
Citació bibliogràfica: | International Journal of Sports Medicine. 2020, 41(14): 1032-1038. https://doi.org/10.1055/a-1186-1316 |
Resum: | The main aims of this study were: 1) to compare 1-minute RMSSD measurements using different stabilization times between them and also with the criterion; and 2) to determine the agreement between every 1-minute RMSSD measurement with the criterion in professional soccer players. Seven hundred eighteen HRV measurements from professional soccer players were taken. HRV was calculated from 5 to 10 minutes (criterion) and from 1-minute windows with different pre-stabilization times. Friedman and post-hoc tests were applied to compare 1-minute and criterion measurements. Effect size was considered to describe magnitude of change. To determine agreement, Spearman’s correlation was applied, and Bland–Altman analysis was also done between each ultra-short HRV time window and the 5-minute HRV criterion period. The 1-minute HRV without any pre-stabilization time was the only one different from all the other 1-minute measurements that included 1 or more minutes of pre-stabilization (p<0.001). One-minute HRV measurements with 1 or more minutes of pre-stabilisation were highly correlated with those for the criterion period. One-minute HRV without pre-stabilization showed the lowest correlation and the highest bias from the criterion. It is concluded that 1-minute HRV measurements with a prior 1-minute or longer pre-stabilization time are valid to measure HRV in professional male soccer players. |
Patrocinadors: | The authors gratefully acknowledge the support of a Spanish government subproject Mixed method approach on performance analysis (in training and competition) in elite and academy sport [PGC2018-098742-B-C33] (Ministerio de Ciencia, Innovación y Universidades, Programa Estatal de Generación de Conocimiento y Fortalecimiento Científico y Tecnológico del Sistema I+D+i), that is part of the coordinated project New approach of research in physical activity and sport from mixed methods perspective (NARPAS_MM) [SPGC201800X098742CV0]. |
URI: | http://hdl.handle.net/10045/110909 |
ISSN: | 0172-4622 (Print) | 1439-3964 (Online) |
DOI: | 10.1055/a-1186-1316 |
Idioma: | eng |
Tipus: | info:eu-repo/semantics/article |
Drets: | © Georg Thieme Verlag KG Stuttgart · New York |
Revisió científica: | si |
Versió de l'editor: | https://doi.org/10.1055/a-1186-1316 |